Three-phase power for ASICs: 230 V, 400 V, circuit breaker and power draw

Author: Updated 4 min read

Most Czech houses have a three-phase connection of 3 × 230/400 V with a main circuit breaker of typically 3 × 25 A. Small miners up to 1.7 kW run from an ordinary 230 V socket, air-cooled machines of around 3.5 kW need their own circuit and hydro machines of 5.5–12 kW need a three-phase 380–415 V supply. Before connecting a larger machine, always have the supply assessed by an electrician – a miner is a continuous load 24 hours a day, not a short peak like a kettle.

Summary

  • A single 230 V phase with a 16 A breaker can carry about 3 kW continuously, or up to 2.9 kW with a margin.
  • A 3 × 25 A household connection theoretically offers 17 kW, but for continuous load and normal household use you should count on much less.
  • Bitmain hydro machines (Hyd series) are powered by three-phase 380–415 V and load all three phases evenly.
  • A larger main breaker means an application to the distributor and a higher monthly capacity charge.

Which machine to connect where

Machine power draw Example Power supply Current
up to 0.5 kW Avalon Nano 3S, Fluminer L2, VolcMiner D1 Mini ordinary 230 V socket up to 2.2 A
0.8–1.7 kW Avalon Mini 3, Avalon Q, Fluminer T3, Fluminer L1 Pro 230 V socket, ideally on a separate circuit 3.5–7.3 A
2.4–4 kW S21 Pro+, S21++, Z15 Pro, L9 dedicated 230 V circuit (often 220–277 V) 11–17 A
5.3–6 kW S21+ Hyd, S23 Hyd, S19 XP+ Hyd three-phase 380–415 V around 8–12 A per phase
8–12 kW S23e Hyd 2U, S21e XP Hyd 3U three-phase, industrial connection 13–18 A per phase

Calculating the current is simple: single-phase I = P ÷ 230 V, three-phase I ≈ P ÷ (1.73 × 400 V). The exact voltage and maximum current are given in the machine's manual – for example, according to the manufacturer the Antminer S21+ Hyd needs 380–415 V and at most 12 A.

How many miners a household breaker can handle

Example for a house with a 3 × 25 A main breaker:

  • The theoretical maximum is 3 × 25 A × 230 V = 17.25 kW.
  • Continuous load should stay below roughly 80 % of the breaker rating, i.e. around 4.6 kW per phase.
  • From this you have to subtract normal household use – cooking, water heating, the washing machine, a heat pump.

In practice, a house with a 3 × 25 A breaker can handle one hydro machine of around 6 kW, or one or two air-cooled machines of 3.5 kW each on different phases. For more machines you need a larger breaker.

What not to forget

  • Phase distribution – spread single-phase machines evenly across L1, L2 and L3 so that no phase is overloaded.
  • Cable cross-section and circuit breaker – an ordinary socket circuit has 2.5 mm² copper cable and a 16 A breaker. A larger machine may need a heavier cable. An electrician will decide.
  • Extension leads and splitters – do not use them for a miner; continuous current heats them up.
  • RCD and inspection – a new circuit for a miner should have an electrical inspection.
  • Reserved capacity – increasing the main breaker is requested from the distributor (ČEZ Distribuce, EG.D, PREdistribuce) and raises the monthly charge. The price per kWh also depends on the tariff – see How much electricity for mining costs.
  • PDU – several machines in one place are connected via a distribution board or a PDU with a breaker for each machine.

When hosting is the better choice

If the connection and inspection would cost more than a few months of hosting, or you do not want to deal with noise and heat, running the machine in a data centre makes sense. You will find a comparison in the article ASIC miner hosting: at home, in Czechia or abroad.

What next

Indicative information, not an electrical installation design. Have new circuits installed by a licensed electrician.

Frequently asked questions

Can I plug an ASIC miner into an ordinary socket?
Small miners up to 1.7 kW, yes, ideally on a separate circuit. Air-cooled machines of around 3.5 kW need their own circuit, and hydro machines need a three-phase 380–415 V supply.
How many miners can a 3×25 A breaker handle?
In practice one hydro machine of around 6 kW, or one or two air-cooled machines of 3.5 kW each on different phases, depending on the household's normal consumption. Keep continuous load below roughly 80 % of the breaker rating.
Does a hydro miner need 400 V?
Yes, Bitmain Hyd series hydro machines are powered by three-phase 380–415 V. For example, according to the manufacturer the S21+ Hyd draws at most 12 A per phase.
How do I increase the main circuit breaker?
By applying to the distributor (ČEZ Distribuce, EG.D or PREdistribuce). A larger breaker raises the monthly capacity charge and often requires an electrician to modify the connection.

This text was prepared with the help of AI. Facts, figures and procedures were checked by Yegor.