How to find the Antminer log (kernel log): a step-by-step guide

You will find the Antminer log in the miner's web interface. Enter the machine's IP address in your browser, log in (Bitmain's default credentials are root / root) and open Miner Log at the bottom left. On older firmware, the log is in the System → Kernel Log menu. You can then download the log as a ZIP using the Download Log button, or copy it into a text file.
Summary
- The log (kernel log) is a record of what the miner has been doing since it was switched on: loading the hash boards, the number of chips found, fans, temperatures, power supply and the pool connection.
- Bitmain distinguishes between the current log (only since the last start) and the history log (a limited record of earlier days). When you restart the miner, the current log starts again.
- Menu names differ by firmware version: Miner Log, Server log, Kernel Log or Miner → Log. The content is the same.
- The most common messages concern fans (fan lost), chips on the board (find 0 asic), temperature sensors, the power supply and the pool.
- Save the log before sending the miner in for repair. Diagnostics will then be faster.
What you will need
- The miner's IP address on your local network. See step 1.
-
Login credentials. Bitmain lists the default user
rootand passwordroot. If someone has changed them, the new password applies. On some newer units the password may be different – look for it on the label or in the model's documentation. - A computer on the same network as the miner. Bitmain recommends Google Chrome or Firefox.
- For the IP Reporter tool, a Windows computer. Bitmain does not support other systems for this tool.
Step 1: Find the miner's IP address
- In your router: find the new device in the list of connected devices (DHCP). You can often recognise it by its name or MAC address.
- With Bitmain IP Reporter: download it from the Bitmain support site (Firmware Download → Others section), unzip it and run it. Allow it network access and click Start. Then briefly (about 1 second) press the IP Report button on the miner. The address will appear in the program window.
IP Reporter only works when the miner is running normally and is on the same network segment as the computer. We cover connecting the miner and finding its IP in more detail in the guide How to connect an ASIC miner.
Step 2: Log in to the web interface
- Enter the IP address in your browser's address bar, for example
http://192.168.1.50. - Enter the username and password.
- If the page does not load, try another browser, clear the cache or use another computer. Also check that the IP address has not changed after the machine was moved.
Security: if the machine still uses the default root password, change it in the System menu. Bitmain itself warns that an attacker can change the web interface or password on a compromised miner. Write the new password down – without it, you can only access the machine by restoring factory settings.
Step 3: Open the log
Where you find the log depends on the firmware version. Bitmain describes two versions of the interface:
| Interface | Where the log is | Typical machines |
|---|---|---|
| Newer Bitmain interface (19 series from 2021 and newer machines) | The Miner Log link at the bottom left, in some translations Server log. Inside, you choose the current or history log. | S19 XP, S21, T21, L7, L9 and other machines with newer firmware |
| Older interface | The System → Kernel Log menu | S9, T9, S17 and machines with older firmware |
If you cannot find either item in the interface, you most likely have a different firmware version. Look through the System and Miner menus. If the machine runs firmware from another vendor (Braiins OS, Vnish, LuxOS and similar), the log is elsewhere and you will find the procedure in that firmware's documentation.
Which log to open:
- Current log – when the miner is faulty right now. It only records the time since the last start.
- History log – when the miner runs unstably or when you want to see what happened earlier.
Do not restart the miner before saving the log. After a restart, the current log starts from scratch and the error disappears from it.
Step 4: Download or copy the log
Download as ZIP (newer interface)
- Click Miner Log and then Download Log.
- For the current state, leave today's date. For history, tick Choose All or only the days you need.
- Scroll down and click Download. A compressed file with the logs will be downloaded.
- If the file is too large, untick Choose All and download only the last few days.
Copying into a text file
- Open the log and select all of it from the first line to the last. For a long log, click the first line, scroll to the end and Shift-click the last line.
- Copy it (Ctrl+C).
- Create a new text file and name it after the miner's IP address, e.g.
192.168.1.50.txt. With several machines, you will not get the logs mixed up. - Paste the text (Ctrl+V), check that all of it was copied and save the file.
Step 5: Send the log to the service centre
Send the service centre the log file together with:
- the miner's model and serial number (from the label),
- what is happening – for example “one board is missing”, “it shuts down after an hour”, “it reports a fan error”,
- when the problem started and what you have already tried (restart, another cable, cleaning).
The log may contain the pool address, the worker name and details of your network. So only send it to someone you trust and do not post it in full in public forums.
Hydro and immersion miners
Hydro (Hyd) and immersion (Imm) versions of Antminers have the same web interface, so you find the log the same way. Bitmain does not have a separate log guide for these machines on its support site. The difference is in what temperature messages mean: on a machine without fans, overheating usually points to the cooling circuit – the inlet liquid temperature, the flow rate or air in the circuit. For the S19 Hydro, for example, Bitmain specifies an inlet water temperature of 20–40 °C. You will find the specific values for your model in its specifications.
How to read the most common errors in the log
The exact wording of messages differs by model and firmware. Look in the log for words such as ERROR, fail, fan, asic, temp, eeprom or power off. “Chain 0, 1, 2” identifies the hash boards by the port they are connected to.
| Log message | What it means | What to do |
|---|---|---|
ERROR_FAN_LOST, fan lost, Fan lost or Fan speed low, Sweep error string = F:1
|
A fan is not reporting its speed or is spinning much more slowly than the others. | Check that the fan connector is seated properly and the cable is not damaged. Try a working fan. If that does not help, the control board may be faulty. |
Chain X only find 0 asic, will power off hash board X, detect 0 chips
|
The hash board on that port found no chips and the miner switched it off. | Switch the machine off, disconnect and reconnect the board's data cable. Bitmain also recommends checking the power supply and grounding. If the error persists, the board needs repair. |
find N asic (fewer chips than the board should have) |
The chip chain is broken – the miner cannot see the chips beyond the faulty point. | Restart and check the cables. If the chip count remains lower, the hash board usually needs repair. |
fail to read pic temp, temp lost, Read Temp Sensor Failed, Sweep error string = J:6
|
The miner cannot read the temperature sensor or the control circuit (PIC) on the hash board. | Reconnect the cables and install the latest official firmware. If the error remains, the board needs servicing. |
EEPROM … error, ERROR_EEPROM_INFO
|
An error in the memory where the hash board stores its data. | Bitmain recommends updating the firmware or restoring the control board via an SD card. If that does not help, the board goes in for repair. |
ERROR_POWER_LOST, Sweep error string = V:1
|
A power problem, most often with the power supply unit (PSU). | Check the power cable, the PSU control cable and that the copper bus bars are seated properly. If everything fits, replace the PSU or have it repaired. |
ERROR_TEMP_TOO_HIGH, Sweep error string = P:1, overtemp protection |
Overheating protection has kicked in and the miner has stopped mining. | Clean the dust from the heatsinks, clear the air intake and exhaust, and lower the intake air temperature. For the 19 series, Bitmain specifies an operating temperature of 5–35 °C. On hydro machines, check the cooling circuit. |
A high number of CRC errors |
Unstable communication with the chips. | Reflash the official firmware and try another power supply. |
stratum connection timeout, retry after 30 seconds
|
The miner cannot connect reliably to the pool. | Check the pool address including the port, the worker name and the internet connection. |
net lost, lost internet … poweroff
|
The miner was without internet for a long time and shut down. For the L7, Bitmain states a limit of 20 minutes. | Check the network cable, the port on the router or switch and the network settings. |
The table is for guidance only. One message can have several causes and may be worded slightly differently on each model. We explain why one faulty chip also “hides” the chips after it in the article Hashboard. An overview of typical faults by symptom can be found in the article ASIC miner fault.
You do not need to install different firmware to read the log. If you update the firmware, use the official version for your model from Bitmain's website.
When to send the log to us
If the error persists after a restart, checking the cables and cleaning, send us the log. This applies especially to messages about chips, EEPROM, temperature sensors and the power supply – these usually cannot be fixed at home. We can often advise based on the log alone.
- At our ASIC miner service centre in Prague we repair hash boards, power supplies, control boards and cooling of Antminers of all series, including Hyd and Imm versions.
- Just want to find out what is faulty? Order an ASIC miner diagnostic. You pay only after it is done, and it is free if we carry out the repair.
- You can bring the miner to our shop at Rostovská 260/2b, Praha 10 (Mon–Fri 9:00–17:00), or send it to us. You will find our phone number and e-mail on the Contact page.
Add the model, serial number and a description of the fault to the log. Diagnostics will then be faster.
What next
- Save the log as soon as the error appears, and only then restart the miner.
- Change the default password if you have not done so yet.
- If the same error persists even after the basic steps, send the log to the service centre together with the model and serial number.
- For what the individual error codes mean, see our overview Antminer and Whatsminer error codes.
Sources
- Bitmain: downloading the current log
- Bitmain: downloading the history log
- Bitmain: how to copy the Kernel Log into text
- Bitmain: common problems and solutions for the Antminer 19 series
- Bitmain: S19 XP log diagnostics
- Bitmain: L7 diagnostic logs
- Bitmain: Kernel Log on the S17 series
- Bitmain: Antminer 19 series interface
- Bitmain: IP Reporter
- Bitmain: I know the IP but cannot access the interface
- Bitmain: S19 Hydro specifications
- D-Central: Antminer S19 kernel log errors
Frequently asked questions
Where do I find the kernel log on an Antminer?
What is the default Antminer login?
Why can't I see an error in the log that happened yesterday?
How do I send the log to the service centre?
What does the message find 0 asic mean in the log?
Do I need to install different firmware to get the log?
This text was prepared with the help of AI. Facts, figures and procedures were checked by Yegor.